): The duration (in minutes) the ceramic remains at the peak firing temperature. Vacuum On ( V1cap V sub 1 ) / Vacuum Off ( V2cap V sub 2
Use the keys to adjust the value to match your ceramic manufacturer’s data sheet.
Requires standard temperature checks (e.g., "Silver Test") for accuracy Optimized for Ivoclar materials like IPS Empress and E.max
Press or Store to save the changes to that specific program. Repeat for all parameters. 4. Standard Operating Procedures (SOP)
The P95 furnace is designed for ease of use, with a straightforward interface. Ivoclar Programat P95 Manual
Place your prepared ceramic restoration onto a firing tray utilizing a firing pillow or metal peg. Ensure the restoration does not touch the thermocouple or the inner walls of the chamber. Initiate: Press the START button. Automatic Cycle: The P95 will execute the drying time (
Run a dedicated furnace de-contamination cycle (purging program) using carbon firing blocks to remove metal oxides. Semi-Annual Maintenance
Programs P01 to P08 are pre-set for standard firings (e.g., glaze or dentin) but remain partially adjustable.
To extend the lifespan of your Programat P95 and ensure consistent aesthetic results, follow a strict maintenance schedule. Silver Wire Calibration Test ): The duration (in minutes) the ceramic remains
Unlike standard ceramic furnaces (max ~1050°C), the P95 operates reliably up to . This paper serves as a technical manual, dissecting the hardware, software (Programat CS4), firing parameters, and preventative maintenance required to achieve clinical success.
is a recognized, reliable, and fully automatic vacuum dental ceramic furnace designed to meet the high-precision needs of dental laboratories . As a cornerstone for porcelain firing, understanding its operational nuances is vital for achieving optimal results. This article serves as a comprehensive guide to the Ivoclar Programat P95 manual
): The peak temperature required to mature the specific ceramic material. How long the furnace remains at the peak temperature. Vacuum Parameters ( V1cap V sub 1 V2cap V sub 2 ): V1cap V sub 1
| Cycle type | Typical temp | Hold time | Vacuum | |------------|--------------|-----------|--------| | e.max Press (200g ring) | 920–940°C | 15–20 min | Yes | | e.max Crystallisation | 840–850°C | 25–30 min | No | | Empress Esthetic | 1070°C | ~10 min | Yes | Repeat for all parameters
Available in 110–120V AC or 220–240V AC models (50/60 Hz). Power Consumption: Max 1500W during peak heating cycles. Maximum Temperature: 1200°C (2192°F).
To maintain the accuracy of the P95, regular maintenance is essential.
Proper placement of the furnace extends the lifespan of the internal electronics and prevents fire hazards. Selecting the Location Place the furnace on a flat, heat-resistant table.