Utilizes a scattered infrared (I.R.) light method to measure oil PPM (parts per million) in the effluent.
For marine engineers, the manual provides Modbus communication tables. The S3000 communicates with the ship's Integrated Automation System (IAS), sending real-time data on flow rates, total tons discharged, and oil content back to the bridge or engine control room.
Uses a multi-cell sensor (Si-photodiode) to detect oil content in PPM.
Follow these steps to discharge oily water mixtures within legal parameters: ODME S-3000 Testing Procedures Guide | PDF | Pump - Scribd
The system continuously samples the oily water mixture being discharged overboard, calculates the instantaneous oil discharge rate, logs the total oil discharged, and automatically triggers an alarm or stops the discharge valve if regulatory limits are breached. The S-3000 is approved in accordance with IMO Resolution MEPC 108(49) and is fully compatible with both crude oils and refined petroleum products. Key Components of the S-3000 odme s3000 manual pdf
Sets the Total Oil Limit (1/30000 of the cargo quantity). Key 7: Resets the Total Oil counter for a new voyage.
The ODME S-3000 is engineered to satisfy stringent global environmental mandates. It is type-approved under and MEPC.240(65) . This certification makes the unit fully compliant for monitoring crude oils, "black" products (heavy fuels), "white" products (clean distillates), and complex biofuel-petroleum blends. ODME S-3000 Operation Manual | PDF | Oil Tanker - Scribd
Measures the volume rate of the water being pumped overboard. This data is critical for calculating the total quantity of oil discharged. 4. The Overboard Discharge Valve & Recirculation Valve
As the operator or engineer of an S-3000 ODME, you are responsible for its correct use and upkeep to ensure it functions reliably during all ballasting operations. The following guide provides the essential steps for manual operation, calibration, and maintenance, derived from technical documentation and service guidelines. Utilizes a scattered infrared (I
Clean the internal glass tube of the oil content meter manually. Test the manual override keys.
Once you download the , do not read it cover to cover. Use the search function (Ctrl+F) to find these specific keywords immediately:
The ODME S3000 consists of several interconnected modules working in real-time to analyze bilge or ballast water before it passes through the overboard discharge valve.
: Wait for the ppm reading to stabilize. If the reading is within permissible MARPOL limits (under 15 ppm or meeting the 30 L/nm criteria depending on the zone), select "Overboard Discharge Mode." Uses a multi-cell sensor (Si-photodiode) to detect oil
Limit switch failure on the overboard or recirculation valve.
Ensure the system is powered on and the fresh water flush has been completed to clean the sensor.
If the oil ppm, ship speed, and flow rate match legal limits, the system will allow the overboard valve to open.