For long parts, measure the angle near both the left and right ends of the bed. This helps the Amada CNC adjust for crowning or uneven tool wear.
A precision-machined reference gauge (typically 90 degrees) used to zero out the device. 2. Step-by-Step Operating Instructions
The CNC will automatically recalculate the depth of the ram for the corrective bend. 4. Calibration Procedures
The DigiPro system functions by mechanically reading the inside or outside angle of a bent workpiece and converting that physical orientation into a digital signal. Understanding its hardware is crucial for proper operation. amada digipro manual
The Amada DigiPro is a specialized digital protractor that integrates with Amada’s AMNC and NC9 control systems. Instead of using traditional visual protractors or mechanical gauges, the DigiPro uses electronic sensors to read the actual bent angle of a workpiece. Key Components
The Amada DigiPro is a —essentially a digital protractor—designed to ensure bend angles are precise and consistent. What sets it apart from traditional angle measurement methods is its wireless data transmission capability . After measuring a bend angle, the DigiPro transmits the value wirelessly to the press brake’s numerical control (NC), which then automatically corrects the program as needed to achieve the target angle.
If the DigiPro displays inconsistent readings, it requires recalibration. Standard 90-Degree Calibration Obtain a certified, precision 90-degree master square. For long parts, measure the angle near both
The operation of the Digipro is designed to be intuitive, allowing operators to measure angles directly on the workpiece.
It acts as the Rosetta Stone for Amada’s robust but complex control system. If you are buying a used Amada machine and it does not come with this manual, You cannot efficiently edit programs or debug alarms without the code definitions contained within these pages.
This article serves as a comprehensive guide based on the principles of the , covering setup, operation, calibration, and troubleshooting for the Digipro CD2000 system. 1. Introduction to the Amada Digipro System Guidelines for cleaning the device
While a full troubleshooting guide is contained within the official manual, operators can also refer to general maintenance advice, such as the need for "regular calibration, cleaning, and inspection" to keep the equipment accurate and reliable.
Clean both the transmitter lens on the DigiPro and the receiver lens on the CNC. Check/replace batteries. Ensure you are within the designated wireless range.
Guidelines for cleaning the device, replacing batteries (if applicable), calibrating the angle sensor, and performing routine inspections.
In this mode, accessed from the main menu, the device acts as a standalone high-precision digital protractor for any bent part.