The official user manual for the Leica TPS1200+ series is the primary document for the TCR 1203. This manual is designed to be a comprehensive field reference, covering everything from basic setup to advanced surveying applications.
Ensure the EDM mode is switched to PinPoint or Reflectorless within the configuration menu when shooting directly to surfaces without a prism. The system automatically defaults to a 0.0 mm constant.
If you are looking for the exact page-by-page PDF manual for the Leica TPS1200 / TCR1203 series to lookup specific error codes or schematic diagrams, ensure you download the official or User Manual directly from Leica Geosystems' official portal (myWorld @ Leica Geosystems) or an authorized distributor to guarantee you have the correct documentation for your specific firmware version.
: Clean the objective lens and eyepiece only with specialized optical cloth or lens wipes to prevent scratching the anti-reflective coatings. Need the Official PDF Manual? Total Station Leica Tcr 1203 Manual
: The TCR 1203 can be paired with a System 1200 RX1250T/Tc controller for remote operation. It is also compatible with the ATX1230 GG SmartStation, which integrates GNSS and total station technologies.
Follow the clear on-screen step-by-step instructions. The instrument will prompt you to sight a distinct target point approximately 100 meters away in Face 1, measure, then automatically invert to Face 2 to repeat the measurement.
Absolute Constant = +17.5 mm (Leica Constant = +17.5 mm). The official user manual for the Leica TPS1200+
: Available in R100, R300, or R400 versions, allowing measurements up to 400+ meters without a prism.
Refer to the troubleshooting section of the manual if you encounter issues.
: The manual recommends periodic "Check & Adjust" procedures to calibrate the horizontal collimation and tilting axis inclination. The system automatically defaults to a 0
To adjust EDM settings, navigate to . Here you can also input atmospheric PPM corrections by altering the current temperature and barometric pressure values. 6. Maintenance and Field Calibration
Houses the battery compartment (using GEB221 or GEB211 lithium-ion batteries) and the CompactFlash card slot for data export. 3. Step-by-Step Instrument Setup and Leveling
Align the instrument parallel to two of your footscrews. Turn the screws in opposite directions to center the electronic bubble on that axis.
For more detailed information, it's recommended to consult the official Leica TCR 1203 manual or contact a Leica representative for further assistance.
Automates the measurement process for efficient surveying. 4. Job Management and Data Handling